252569
gas type, pressure Auxiliary burner Normal burner large burner Triple burner
Wobe Number
Standard Quick
max min max min max min max min max min
Natural gas H
Wo=45,7÷
54,7 MJ/ m
3
,
Natural gas E ,
Natural gas E+
Wo=40,9÷54,7 MJ/m
3
G20,
p=20mbar
Nom. therm. load
(kW)
1 0,6 1 0,6 1,90 0,46 3 0,76 3,5 1,56
Consumption
(l/h)
95,21 34,4 95,21 34,4 180,9 43,8 285,64 72,4 333,2 148,5
Nozzle type
(1/100mm)
77 - 78 - 104 - 129 - 140 •
Nozzle code
162081 162082 162083 162084 162085
Liquid gas 3B/P
Wo=72,9÷87,3MJ/m
3
G30
p=30 mbar
Nom. therm. load
(kW)
1 0,36 1 0,36 1,90 0,46 3 0,76 3,5 1,56
Consumption
(l/h)
71,7 26,2 71,7 26,2 138,1 33,4 215,0 55,3 254,5 113,4
Nozzle type
(1/100mm)
50 24 50 24 69 26 87 33 93 57
Nozzle code 162162 162162 162164 162165 162166
• Regulation valves that are factory-built-in are intended for liquid gas; however, the valves are set
for operation with the type of gas for which the appliance is factory-preset.
• When adapting the appliance for use with another type of gas, the regulation screw (valve)
should be fastened or release to correspond with the required gas fl ow / throughput (however,
the regulation screw should not be released more than by 1.5 rounds from the position in which it
is completely fastened).
Burner power is indicated by observing the upper Hs caloric value.
Warning: these tasks may only be carried out by a qualifi ed technician, authorized by the
gas distributing company or authorized service center!
19
Nozzle table